ENVIRONMENT
























      OUT IN THE








      FIELDS?













          xposure to              system (tingling, muscle      sources of EMFs exist and   The Control of
       E Electromagnetic          contraction, heart arrhythmia)   at what frequency range.  Electromagnetic Fields at Work
       Fields (EMFs) is not a new   and thermal stress (rises in   n Prove and ensure that   Regulations 2016 provides
       phenomenon. Everyone       body/limb temperature).       exposure is below Exposure   a non-exhaustive list of ‘low
       is constantly exposed to     Indirect effects include    Limit Values (ELVs)      exposure equipment’ where no
       a complex mix of weak      interfering with pacemakers   n Implement control measures   further action is required, apart
       electric and magnetic fields   and body implants.        – for example, periodic   from documenting findings
       from telecommunications,     Those most at risk          fixed wire testing, PAT   (except where employees
       domestic appliances, industrial   from EMFs are:         testing, cable shrouding   are at particular risk). These
       equipment and the generation   n Expectant mothers: working   and the use of trained and   include office equipment
       and transmission of electricity.  with specific levels of EMFs   certified electricians  (photocopiers, computers,
         EMFs are magnetic and      could result in a greater risk                       IT equipment and phones),
       electromagnetic fields with   n Workers with active      HSG281 is a guide to the   mobile phones and landlines.
       frequencies up to 300 GHz    implanted medical devices:   Control of Electromagnetic   Sources of EMF that may
       are produced whenever a      eg cardiac pacemakers     Fields at Work Regulations   exceed exposure limit values
       piece of electrical or electronic   n Workers with passive   2016 and refers to two sets of   include electrical circuits
       equipment is used. They are   implanted medical devices:   values: Action Levels (ALs) and   that are bundled together
       present in most workplaces   eg orthopaedic implants   Exposure Limit Values (ELVs).   and collectively carry an
       and exposure to high levels   or joints, pins and plates  ELVs are the legal limitations   unbalanced current of >100A.
       of EMFs can give rise to either   n Workers with body-  on the exposure of employees   It is wise to listen your
       direct or indirect effects.  worn medical devices:     to EMFs and primarily relate   employees and check on their
         Direct effects include nausea,   eg hearing aids     to the levels of exposure to   well-being, since they could be
       vertigo, a metallic taste in the                       EMFs within the body. These   exposed to electromagnetic
       mouth, flickering sensations in   The law requires     are often impossible or difficult   hazards they cannot see.
       peripheral vision and auditory   employers to:         and expensive to measure
       effects such as perception   n Identify those employees at   directly. For this reason, a   n FOR MORE
       of clicks or buzzing. Health   particular risk (see above)  separate set of values, known   INFORMATION, CONTACT
       effects can include nerve   n Assess the levels of EMFs that   as ALs, has been produced   YOUR REGIONAL HS&E
       stimulation, effects on the   employees are exposed to by   relating to quantities that can   ADVISER OR VISIT WWW.
       central and peripheral nervous   identifying the areas where   be measured more easily.  BRITISHPRINT.COM/HSE